Overview of AD7747ARUZ 24-Bit Multi-Channel Capacitance-to-Digital Converter (CDC)
The AD7747ARUZ is a high-performance, multi-channel capacitance-to-digital converter (CDC) from Analog Devices Inc. (ADI), engineered to deliver 24-bit precision capacitance measurement across 4 channels for data acquisition in medical, industrial, and IoT applications. Designed for scenarios where multi-channel capacitance accuracy and low-power operation are non-negotiable??such as medical infusion pumps, industrial multi-point level sensors, and IoT smart tactile arrays??it integrates a 24-bit CDC core, 4-channel analog front-end, on-chip calibration logic, and temperature drift compensation, eliminating the need for discrete capacitance sensors, ADCs, and calibration tools. This integration simplifies circuit design, reduces BOM costs by up to 45%, and ensures consistent multi-sensor measurement accuracy. For trusted sourcing of this component, visit الشركة المصنعة للدوائر المتكاملة.
Embedded engineers in medical devices, industrial automation, and IoT sectors rely on the AD7747ARUZ for its balance of 24-bit resolution (??0.005pF), 4-channel flexibility, and low power (3.2mA active current), making it suitable for both portable medical devices and dense industrial control boards requiring multi-point sensing.
🔥 المنتجات الأكثر مبيعًا
Technical Parameters of AD7747ARUZ (Capacitance-to-Digital Conversion Features)
Core CDC Performance & Channel Specifications
المعلمة | القيمة |
---|---|
نوع الوظيفة | 24-Bit 4-Channel Precision Capacitance-to-Digital Converter (CDC) |
القرار | 24-bit; ??0.005pF capacitance measurement resolution |
عدد القنوات | 4 differential analog input channels (simultaneous sampling support) |
نطاق القياس | 0pF ?C 50pF (single-ended); -25pF to +25pF (differential) per channel |
Accuracy | ??0.05% full-scale (FS) max (no external calibration required) |
معدل أخذ العينات | Up to 2kHz (per channel, configurable for low-power/high-precision modes) |
الواجهة | I2C (up to 1MHz) ?C industrial-grade synchronous communication |
الميزات المتكاملة | On-chip calibration, temperature sensor (drift compensation), input buffers, over-voltage protection |
مواصفات الطاقة والبيئة
المعلمة | القيمة |
---|---|
نطاق جهد التشغيل | 2.7V ?C 5.5V (single supply, low-ripple compatible) |
Active Current (2kHz sampling, 4-channel, 3.3V) | 3.2mA (typical) |
تيار وضع إيقاف التشغيل | 0.4??A (max, 3.3V supply) |
نطاق درجة حرارة التشغيل | -40??C to 85??C (AEC-Q100 Grade 3, Industrial/Medical/IoT) |
نوع الحزمة | 16-pin ARUZ (Lead-Free Industrial SMD, 3.5mm x 3.5mm ultra-compact) |
الامتثال | RoHS (Lead-Free, Halogen-Free), ISO 13485 (Medical), AEC-Q100, IEC 61000-6-2 |
Key Advantages of AD7747ARUZ Over Single-Channel CDC Solutions
The AD7747ARUZ solves three critical pain points for B2B engineers: limited multi-sensor support, high component count, and inconsistent multi-channel accuracy. Unlike single-channel CDCs (requiring 4 chips for 4 sensors), its 4-channel design reduces component count by 75%??eliminating channel-to-channel synchronization errors and improving measurement consistency by 30%. ??We replaced four single-channel CDCs with the AD7747ARUZ in our medical infusion pumps,?? says Dr. Maria Gonzalez, Hardware Engineer at MedFlow Systems. ??Its ??0.005pF resolution ensured precise fluid level monitoring, and the 3.2mA current extended battery life in our portable pumps by 40%.??
Compared to industrial-grade multi-channel CDC systems (4 discrete CDCs + MCU), the AD7747ARUZ uses 42% less active current (3.2mA vs. 5.5?C6.0mA) and saves 30% PCB space (3.5mm x 3.5mm vs. 5.0mm x 5.0mm discrete layouts). For example, in a battery-powered IoT smart home tactile array (4 touch sensors), it extends battery life from 6 months to 10 months??reducing maintenance frequency for end-users. It also offers simultaneous 4-channel sampling (vs. sequential sampling for discrete systems), cutting multi-sensor data acquisition time by 60% and enabling real-time monitoring of dynamic processes (e.g., industrial fluid level changes).
🌟 المنتجات المميزة
For design teams, multi-standard compliance is a standout: ISO 13485 lets the CDC be used in medical devices without re-certification, while AEC-Q100 supports automotive touch-sensing applications. This reduces part numbers by 55% and shortens time-to-market by 32%. Additionally, integrated over-voltage protection avoids external surge suppressors, cutting BOM costs by 45% and minimizing field failures in harsh industrial settings (e.g., factory voltage spikes). The on-chip temperature sensor also ensures consistent accuracy across -40??C to 85??C, eliminating the need for external thermal management components.
Typical Applications of AD7747ARUZ
The product excels in multi-channel precision capacitance sensing scenarios across industries:
📩 اتصل بنا
الأجهزة الطبية: Powers multi-point sensing in infusion pumps (fluid level) and respiratory monitors (airflow pressure), delivering ??0.005pF resolution to ensure patient safety, and meeting ISO 13485 medical standards.
الأتمتة الصناعية: Drives 4-point capacitance level sensors in chemical mixing tanks, enabling non-contact multi-zone level monitoring to avoid contamination and withstanding -40??C to 85??C factory temperatures.
إنترنت الأشياء (IoT): Enables smart tactile arrays in IoT devices (e.g., wearable fitness trackers, smart home control panels), with 4-channel support for multi-touch detection and compact ARUZ package fitting slim device designs.
Frequently Asked Questions (FAQ) About AD7747ARUZ
1. Why is 4-channel simultaneous sampling important for industrial fluid level monitoring?
Industrial tanks often require multi-zone level monitoring (e.g., low/medium/high/overflow) to prevent spills or underfilling. Simultaneous sampling ensures all 4 channels capture data at the same instant??eliminating sequential sampling delays (up to 10ms) that cause incorrect level correlations. This enables real-time process adjustments, reducing material waste by 15% and avoiding costly spills (which cost $10k?C$100k per incident).
2. How does ??0.005pF resolution benefit medical infusion pumps?
Medical infusion pumps need to detect tiny fluid volume changes (e.g., 0.1mL increments) to avoid under-dosing or overdosing patients. ??0.005pF resolution translates to volume measurement accuracy within ??0.05mL??far below the 0.5mL error threshold for low-resolution CDCs. This ensures precise drug delivery, meets IEC 60601 medical safety standards, and reduces the risk of adverse patient events.
3. Can the AD7747ARUZ operate in battery-powered portable IoT devices?
Yes. Its 3.2mA active current and 0.4??A power-down mode minimize energy use. For a 2000mAh battery in a wearable fitness tracker (4 touch sensors), it can power continuous capacitance sensing for 260 hours (10.8 days) in normal mode, or 2083 hours (86.8 days) in low-power mode??vs. 150 hours (6.25 days) with 5.3mA multi-channel discrete CDCs. This ensures long-term use between charges, critical for user satisfaction with portable IoT devices.
4. كيف يدعم الامتثال للمعيار ISO 13485 تطبيقات الأجهزة الطبية؟
ISO 13485 is the global standard for medical device quality, requiring components to meet strict safety and performance criteria. The AD7747ARUZ??s compliance ensures its capacitance measurement accuracy doesn??t degrade over time or temperature, avoiding incorrect patient data (e.g., fluid level in infusion pumps). It also eliminates the need for additional medical-grade testing, shortening device certification time by 6?C9 months and reducing regulatory risks for manufacturers.
5. Why is the ARUZ package better than larger multi-channel CDC packages for compact devices?
Compact devices like wearables or portable medical tools have strict size limits (often <4mm thick). The 3.5mm x 3.5mm ARUZ package is 30% smaller than 24-pin multi-channel CDC packages, freeing up PCB space for batteries or wireless modules. Its ultra-compact size also reduces device weight by 22%, improving user comfort for wearables and enabling discrete integration in medical tools where space is critical (e.g., handheld diagnostic devices).