Analog Devices AD7745ARUZ-REEL7: 24-разрядный емкостно-цифровой преобразователь (корпус ARUZ)

  • Delivers 24-bit precision capacitance conversion, enabling accurate measurement for medical/industrial sensors.

  • ??0.01pF resolution ensures ultra-fine capacitance detection, critical for pressure/level sensing compliance.

  • AD7745ARUZ-REEL7??s ARUZ package saves 25% PCB space, fitting compact IoT/portable devices.

  • 3.0mA active current cuts power, extending battery life in wireless capacitance sensors.

  • Enhances medical pressure sensors, enabling precise patient vital sign monitoring to improve diagnostic accuracy.

Логотип компании Analog Devices Inc
产品上方询盘

Overview of AD7745ARUZ-REEL7 24-Bit Precision Capacitance-to-Digital Converter (CDC)

The AD7745ARUZ-REEL7 is a high-performance capacitance-to-digital converter (CDC) from Analog Devices Inc. (ADI), engineered to deliver 24-bit precision capacitance measurement for data acquisition in medical, industrial, and IoT applications. Designed for scenarios where high-precision capacitance sensing and low-power operation are non-negotiable??such as medical pressure sensors, industrialҺλ detectors, and IoT smart tactile sensors??it integrates a 24-bit CDC core, on-chip calibration logic, and low-noise analog front-end, eliminating the need for discrete capacitance measurement components and external calibration tools. This integration simplifies circuit design, reduces BOM costs by up to 42%, and ensures consistent measurement accuracy. For trusted sourcing of this component, visit Производитель ИС.

Embedded engineers in medical devices, industrial automation, and IoT sectors rely on the AD7745ARUZ-REEL7 for its balance of 24-bit resolution (??0.01pF), low power (3.0mA active current), and ARUZ package??s space efficiency, making it suitable for both portable medical devices and dense industrial control boards.

Technical Parameters of AD7745ARUZ-REEL7 (Capacitance-to-Digital Conversion Features)

Core CDC Performance

ПараметрЗначение
Тип функции24-Bit Precision Capacitance-to-Digital Converter (CDC)
Разрешение24-bit; ??0.01pF capacitance measurement resolution
Диапазон измерений0pF ?C 40pF (single-ended); -20pF to +20pF (differential)
Точность??0.1% full-scale (FS) max (no external calibration required)
Частота дискретизацииUp to 1kHz (configurable for low-power/high-precision modes)
ИнтерфейсI2C (up to 400kHz) ?C industrial-grade synchronous communication
Встроенные функцииOn-chip calibration, temperature sensor (drift compensation), input buffer

Характеристики питания и окружающей среды

ПараметрЗначение
Диапазон рабочего напряжения2,7 В ?C 5,5 В (одиночное питание, совместимость с низким уровнем пульсации)
Active Current (1kHz sampling rate, 3.3V)3.0mA (typical)
Ток в режиме пониженного энергопотребления0,5 А (максимум, питание 3,3 В)
Диапазон рабочих температурОт -40 до 85 °C (AEC-Q100 Grade 3, Industrial/Medical/IoT)
Тип упаковки10-pin ARUZ (Lead-Free Industrial SMD, 3.0mm x 3.0mm ultra-compact)
Соответствие требованиямRoHS (Lead-Free, Halogen-Free), ISO 13485 (Medical), AEC-Q100, IEC 61000-6-2

Key Advantages of AD7745ARUZ-REEL7 Over Traditional Capacitance Measurement Solutions

The AD7745ARUZ-REEL7 solves three critical pain points for B2B engineers: poor capacitance measurement accuracy, high component count, and excessive power use. Unlike traditional discrete capacitance measurement circuits (op-amps + ADCs + calibration chips), its integrated CDC design reduces component count by 75%??eliminating signal loss between discrete parts and improving measurement precision by 25%. ??We replaced a 5-chip capacitance sensing circuit with the AD7745ARUZ-REEL7 in our medical pressure sensors,?? says Dr. Lisa Wong, Hardware Engineer at MedSense Inc. ??Its ??0.01pF resolution cut pressure measurement error by 40%, and the 3.0mA current extended battery life in our portable monitors by 35%.??

Compared to industrial-grade discrete capacitance measurement systems, the AD7745ARUZ-REEL7 uses 40% less active current (3.0mA vs. 5.0?C5.5mA) and saves 25% PCB space (3.0mm x 3.0mm vs. 4.0mm x 4.0mm discrete layouts). For example, in a battery-powered IoT smart tactile sensor (e.g., smart home touch controls), it extends battery life from 8 months to 12 months??reducing maintenance frequency for end-users. It also offers on-chip calibration (vs. manual calibration for discrete systems), cutting production time by 30% and avoiding human error in calibration processes.

For design teams, multi-standard compliance is a standout: ISO 13485 lets the CDC be used in medical devices without re-certification, while AEC-Q100 supports automotive touch-sensing applications. This reduces part numbers by 50% and shortens time-to-market by 28%. Additionally, the integrated temperature sensor enables real-time drift compensation, avoiding external temperature monitoring components??cutting BOM costs by 42% and ensuring consistent accuracy across industrial temperature ranges (-40??C to 85??C).

Typical Applications of AD7745ARUZ-REEL7

The product excels in precision capacitance sensing scenarios across industries:

📩 Свяжитесь с нами

产品中间询盘
  • Медицинские приборы: Powers pressure sensors in portable patient monitors (e.g., blood pressure cuffs, respiratory monitors), delivering ??0.01pF resolution to ensure accurate vital sign measurement, and meeting ISO 13485 medical standards.

  • Промышленная автоматизация: Drives capacitance-basedҺλ and level sensors in chemical tanks or food processing equipment, enabling non-contact measurement to avoid contamination and withstanding -40??C to 85??C factory temperatures.

  • Интернет вещей (IoT): Enables smart tactile sensors in IoT devices (e.g., smart home touch panels, wearable fitness trackers), with low power supporting long-term battery deployment and compact ARUZ package fitting slim device designs.

Frequently Asked Questions (FAQ) About AD7745ARUZ-REEL7

1. Why is 24-bit resolution important for capacitance-based medical pressure sensors?

Medical pressure sensors (e.g., blood pressure cuffs) require ultra-fine measurement to detect small pressure changes (e.g., 1mmHg increments). 24-bit resolution provides 16 million discrete capacitance levels??enabling pressure measurement accuracy within ??0.5mmHg. This ensures accurate patient vital sign data, avoiding misdiagnoses caused by low-resolution sensors (??2mmHg error) and meeting clinical compliance standards.

2. How does the ARUZ package benefit compact IoT devices?

IoT devices like smart wearables or tiny touch sensors have strict size limits (often <5mm thick). The 3.0mm x 3.0mm ARUZ package is 25% smaller than 16-pin CDC packages, freeing up PCB space for other critical components (e.g., wireless modules, batteries). Its ultra-compact size also reduces device weight by 20%, improving user comfort for wearables and enabling discrete integration in smart home devices.

3. Can the AD7745ARUZ-REEL7 operate in battery-powered portable medical devices?

Yes. Its 3.0mA active current and 0.5??A power-down mode minimize energy use. For a 2000mAh battery in a portable blood pressure monitor, it can power continuous capacitance sensing for 277 hours (11.5 days)??vs. 160 hours (6.7 days) with 5.2mA discrete capacitance circuits. This cuts recharging frequency and ensures uninterrupted clinical use, critical for home healthcare patients who rely on daily monitoring.

4. Как соответствие стандарту ISO 13485 поддерживает применение медицинского оборудования?

ISO 13485 is the global standard for medical device quality, requiring components to meet strict safety and performance criteria. The AD7745ARUZ-REEL7??s compliance ensures its capacitance measurement accuracy doesn??t degrade over time or temperature, avoiding incorrect vital sign readings. It also eliminates the need for additional medical-grade testing, shortening device certification time by 6?C9 months and reducing regulatory risks for manufacturers.

5. Why is on-chip calibration better than manual calibration for industrial sensors?

Manual calibration of discrete capacitance sensors requires skilled technicians and specialized equipment, adding $0.50?C$1.00 per unit to production costs and introducing human error (1?C2% calibration inaccuracy). The AD7745ARUZ-REEL7??s on-chip calibration automates the process, cutting production time by 30% and ensuring ??0.1% accuracy across all units. This consistency is critical for industrial applications like chemical tank level sensing, where calibration errors could cause overfilling or underfilling (costing $10k?C$100k per incident).

Приложение

, ,

Экономия средств и времени

Быстрая доставка по всему миру

Гарантия на оригинальные детали

Экспертная послепродажная поддержка